PRODUCTS SHOW
CONTROLLER of SOLAR WATER HEATER, water proof, 240V, for Australia Newzealand SWH-SRC-001-B

Product Numbers: SWH-SRC-1068-B

Product description:CONTROLLER of SOLAR WATER HEATER, water proof, 240V, for Australia Newzealand

 

 

Model: SWH-SRC-1068-B

 

Application:

It is suitable for integrated pressurized solar system.

It is connected ready, just need you to plug in. Design for Australia and Newzealand specially.

Voltage:240V

Water proof: IP43

 

 

Introduction:

System description 1 collector array – 1 storage tank – 1 pump and auxiliary heating Description: The solar circuit pump (P1) is switched on as soon as the switch-on temperature difference (?Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (?Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.4): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.

 

Technical  data
Range  of  tank  temperature  measuring 0~110oC
Suitable  power  of  electrical  heater 1?,≤  1500W
Inputs 1  x  Pt1000  sensor  (≤500oC)  for  collector  (silicon  cable≤280oC),
2  x  NTC10K,  B3950  sensor  (≤  135oC)  for  tank,  (PVC  cable  ≤105oC),  
Ambient  temperature -10~50  oC
Display Only  suitable  installation  indoors
control  body Water  proof  grade:IP43

 

Main functions:

4.3    Main    menu    DT    O    &    DT    F    Temperature    difference    function
4.4    Main    menu    -    THET    timing    heating
4.5    TEMP    Temperature    main    menu
4.5.1    EM    Emergency    collector    temperature(Emergency    switch-off    temperature    of    collector)
4.5.2    CMX    Maximum    limited    collector    temperature    (collector    cooling    function)
4.5.3    CMN    low    temperature    protection    of    collector
4.5.4    CFR    frost    protection    of    collector
4.5.5    SMX    Maximum    temperature    of    tank
4.5.6    REC    Tank    re-cooling    function
4.5.7    C-    F    Celsius    and    Fahrenheit    temperature    transferring
4.6    HND    Manual    mode
4.7    PASS    Password    setting
4.8    LOAD    Recovery    factory    setting
4.9    Manual    heating
4.10    Holiday    function
4.11    Temperature    query    function
5.    Protection    function
5.1.    Memory    protection
5.2    Screen    protection
6.    Trouble    shooting
6.1    Trouble    protection
6.2    Trouble    checking